Update ha-thermostat-calibration.yaml

This commit is contained in:
Andreas Gammelgaard Damsbo 2025-12-06 11:46:36 +01:00
parent e8d0128b38
commit d036fe802a

View file

@ -9,7 +9,7 @@ blueprint:
corresponding temperature offset entities based on the difference between each corresponding temperature offset entities based on the difference between each
valve's internal sensor and the actual room temperature. valve's internal sensor and the actual room temperature.
⚙️ Example use case: Example use case:
- **area**: Living Room - **area**: Living Room
- **external_sensor**: sensor.living_room_temperature - **external_sensor**: sensor.living_room_temperature
- **rounding_step**: 1.0 - **rounding_step**: 1.0
@ -18,15 +18,15 @@ blueprint:
to match the external sensor reading. Thermostats without offset entities are to match the external sensor reading. Thermostats without offset entities are
automatically skipped. automatically skipped.
Manual correction: Manual correction:
Use the **manual_correction** slider to bias the calculated offset in cases where Use the **manual_correction** slider to bias the calculated offset in cases where
valves tend to stop heating too early or overheat even after calibration. valves tend to stop heating too early or overheat even after calibration.
- Positive value (e.g., +0.3 °C): Valves assume room is warmer → reduce heating sooner - Positive value (e.g., +0.3 °C): Valves assume room is warmer → reduce heating sooner
- Negative value (e.g., 0.3 °C): Valves assume room is cooler → prolong heating - Negative value (e.g., -0.3 °C): Valves assume room is cooler → prolong heating
domain: automation domain: automation
source_url: source_url: https://gdamsbo.dk/forgejo/andreas/ha-thermostat-calibration/raw/branch/main/ha-thermostat-calibration.yaml
input: input:
target_area: target_area:
@ -85,7 +85,7 @@ blueprint:
Additional manual bias applied to computed offsets **before rounding**. Additional manual bias applied to computed offsets **before rounding**.
Use this if valves still behave undesirably after calibration: Use this if valves still behave undesirably after calibration:
- **Positive value** (e.g., +0.1…+1.0 °C): Makes valves think it's **warmer** → **reduces** heating sooner - **Positive value** (e.g., +0.1…+1.0 °C): Makes valves think it's **warmer** → **reduces** heating sooner
- **Negative value** (e.g., 0.1…−1.0 °C): Makes valves think it's **cooler** → **prolongs** heating - **Negative value** (e.g., -0.1…-1.0 °C): Makes valves think it's **cooler** → **prolongs** heating
Recommended start: 0.0 °C. Adjust in small steps (±0.1 °C) and observe behavior. Recommended start: 0.0 °C. Adjust in small steps (±0.1 °C) and observe behavior.
default: 0.0 default: 0.0
selector: selector:
@ -100,9 +100,9 @@ blueprint:
name: Offset entity suffix pattern name: Offset entity suffix pattern
description: > description: >
The text pattern used to identify offset number entities. The text pattern used to identify offset number entities.
By default, looks for entities containing "temperature_offset" or "local_temperature_offset". By default, looks for entities containing "_local_temperature_offset".
Only change this if your devices use a different naming pattern. Only change this if your devices use a different naming pattern.
default: "temperature_offset" default: "_local_temperature_offset"
selector: selector:
text: {} text: {}